Excalibur Commercial Water Softeners Brochure

COMMERCIAL / INDUSTRIAL WATER SOFTENERS When performance & value matters.

SPECIFICATIONS EWS1 EWS1.5 EWS2QC Service @ 15 psi drop Backwash @ 25 psi drop 27 gpm (includes meter & bypass) 27 gpm (includes bypass) 70 gpm 52 gpm 125 gpm 85 gpm TANK APPLICATIONS: Softener Filter 6” - 21” diameter 6” - 21” diameter 12” - 30” diameter 12” - 30” diameter 12” - 48” diameter 12” - 36” diameter Inlet/Outlet Fitting Connections 1” - 1.25” NPT 3⁄4” - 1.5” Sweat 3⁄4” - 1.5” Solvent 3⁄4” - 1” SharkBite® 1.5” Female NPT 2” Female NPT Valve Material Cycles Regeneration Noryl Up to 6 Downflow/Upflow Lead Free Brass Up to 6 Downflow/Upflow Lead Free Brass Up to 6 Downflow/Upflow Operating Pressures Operating Temperatures 20 - 125 psi 40° - 110° F 20 - 125 psi 40° - 110° F 20 - 125 psi 40° - 110° F METER: Flow Rate Range Volume Range (gallons) Totalizer 0.25 - 27 gpm 20 - 1,500,000 gallons Yes 0.5 - 75 gpm 20 - 1,500,000 gallons Yes 1.5 - 150 gpm 20 - 1,500,000 gallons Yes Distributor Pilot 1.050” O.D. Pipe 3⁄4” NPS 1.90” O.D. Pipe 1.5” NPS 2.375” O.D. Pipe 2” NPS Drain Line Connection 3⁄4” Male NPT Standard 1” Male NPT Optional 1.25” Female NPT with 3⁄4” Male NPT Standard 1” Male NPT Optional 1.5” Female NPT Brine Line Connection 3⁄8” or 1⁄2” O.D. Poly Tube Compression 3⁄4” Female NPT 1⁄2” O.D. Poly Tube Compression 1” Male NPT elbow 3⁄4” x 1” Solvent elbow 1⁄2” O.D. Poly Tube Compression Mounting Base Options 2 1/2” - 8 NPSM 4” - 8 UN Quick Disconnect 4” - 8 UN 6” Flange Side Mount Height From Top of Tank 7 3/8” 9.5” with 4” - 8 UN QC Base is 11.2” with 6” Flange QC Base is 11.3” Shipping Weight 4.5 lbs. 21 lbs. 29 lbs. ELECTRICAL: Supply Voltage Supply Frequency Output Voltage Output Current 120V 60 Hz 12V AC 500 mA 120V 60 Hz 12V AC 500 mA 120V 60 Hz 12V AC 500 mA CONTROL VALVES

SPECIFICATIONS EWS2H EWS3 Service @ 15 psi drop Backwash @ 25 psi drop 125 gpm (includes meter) 125 gpm 250 gpm 220 gpm Tank Application: Softener Tank Application:Filter 18” - 63” diameter 18” - 48” diameter 18” - 63” diameter (2) 18” - 63” diameter Inlet/Outlet Fitting Connections 2” Female NPT / 3” Female NPT 2.5” Groove Lock 3” Female NPT Valve Material Cycles Regeneration Lead Free Brass Up to 9 Downflow Lead Free Brass Up to 9 Downflow Operating Pressures Operating Temperatures 20 - 125 psi 40° - 110° F 20 - 125 psi 40° - 110° F METER: Flow Rate Range Volume Range (gallons) Totalizer 1.5 - 125 gpm 10 - 999,000 gallons Yes 3.5 - 350 gpm 10 - 999,000 gallons Yes Distributor Pilot 2.375” O.D. Pipe 2” NPS 3.5” O.D. Pipe 3” NPS Drain Line Connection 2” Female NPT / 2.5” Groove Lock 3” Female NPT Brine Line Connection 1” Male NPT elbow 3⁄4” x 1” Solvent elbow 1” Male NPT elbow 3⁄4” x 1” Solvent elbow Mounting Base Options Quick Disconnect 4” - 8 UN 6” Flange Side Mount Quick Disconnect 6” Flange Side Mount Height From Top of Tank with 4” - 8 UN QC Base is 11.5” with 6” Flange QC Base is 11.6” with 6” Flange QC Base is 12.5” Shipping Weight 50 lbs. 57 lbs. (no meter) ELECTRICAL: Supply Voltage Supply Frequency Output Voltage Output Current 120V AC 60 Hz 20V AC 750 mA 120V AC 60 Hz 20V AC 750 mA CONTROL VALVES

COMMERCIAL / INDUSTRIAL WATER SOFTENER COMPONENTS MOTORIZED ALTERNATING VALVE FEATURES (MAV) • Engineered for duplex alternating system • 1-1/4” to 2” Motorized Alternating Valves • Full porting with minimal pressure loss • Provides for no raw water bypass during regeneration • Low voltage drive assy controlled by valve circuit board • Operating pressures 20psi-125psi • Operating temperatures 40˚ F - 110˚ F • Patent seal spacer stack assy • Hydraulically balanced piston valve • Proven and reliable Excalibur DC drive assy NO HARD WATER BYPASS (NHWB) • Engineered for duplex alternating with progressive flow & system controller applications • 1” to 3” No Hard Water Bypass Valves • 316 stainless & composite materials of construction • Designed for use in multiple tank configurations • Proven and reliable Excalibur DC drive assy • Hydraulically balanced piston valve • Patent seal spacer stack assy • Operating pressures 20psi-125psi • Operating temperatures 40˚ F - 110˚ F • Low voltage drive assy controlled by valve circuit board • Full porting with minimal pressure loss EXCALIBUR SYSTEM CONTROLLER • Excalibur System Controller may operate 2-6 vessels • 1” to 2” Control Valve Engineered Systems • System diagnostic & programming information download • Two fused single pole double throw (SPDT) relay outputs • Front panel displays for time of day, day of week, days until next regeneration, current system flow rate & total system volume utilized • System regeneration types progressive flow, alternator, series, and random options • Solid state processor friendly front panel programming • Front panel LED status indicators for online, standby, and regeneration • Single demand based output meter • Coin cell lithium battery for backup time of day MINERAL TANKS • Excalibur mineral tanks are made of high pressure composite materials - LLDPE liner with FRP filament winding outer shell • Flanged tanks manufactured with continuous seamless inner liner shell with a solid anodize aluminum cast flange • This design provides excellent strength, durability and leak free service • Maximum operating pressure 150psi • Maximum operating temperature 120˚ F • Mineral tanks are NSF 44 & PED certified ASSEMBLED BRINE TANKS • Excalibur brine tanks are rotationally molded of a high density polythylene for exceptional stress-crack resistant properties increased durability • Injection molded plastic HDPE grids available for dry salt storage applications • Brine float to eliminate brine tank overflowing • Safety float brine valve delivers water demand for high flow brining application and refill • Float eliminates pre-checking during brine refill when air is in the brine line could cause excessive flow rates • Brine float is enclosed inside a brine well with cap and secured with a two piece overflow set • Air check valve to initiate slow rinse cycle after brining complete RESIN • Excalibur C-800 water softening resin has a minimum 8% cross link gel type sodium form high capacity polystyrene ion exchange resin • Performance maximum capacity of 30,000 grains per cubic foot when regenerated with 15lbs of salt • Resin is solid containing no plates shells agglomerates or other shapes for high efficiency maximum capacity performance • Excalibur premium water softening resins are manufactured in Canada • Tested & certified to NSF ANSI 44 and 61 with WQA Gold Seal

COMMERCIAL / INDUSTRIAL WATER SOFTENER COMPONENTS COMMERCIAL / INDUSTRIAL WATER SOFTENER APPLICATIONS GRAVEL SUPPORT BED • Excalibur uncrushed gravel has a highly spherical shape that promotes good flow and even distribution support bed • Gravel will maintain the quality of the softened water • Multi depth layered gravel support bed for maximum flow rates with minimum pressure drop WATER DISTRIBUTION • Excalibur high impact FDA approved hub and lateral high flow distributors are utilized to evenly collect and distribute the flow of water over the entire resin bed. PROGRESSIVE FLOW • Progressive flow provides minimum to maximum peak flow rates utilizing one or all of the vessels in the design configuration to satisfy current demand. This system will utilize and operate outlet isolation valves with a predetermined flow rate set point to bring online additional units to meet peak flow rate requirements. This system configuration determines the need to regenerate based on a unit reaching zero capacity or day override. Commercial Applications Condominium Apartment buildings Assisted Living Facilities Motels Hotels Hospitals Office Buildings Agriculture Car Wash Trailer Parks Schools Laundry Mats Gas Stations Restaurants Health Clubs Grocery Stores Industrial Applications Boiler Pre Treatment Pharmacutical Paint Booths Process Water Steel Industries Aerospace Food Processing Bottling Plants Cooling Tower Petro Chemical Electronics Pulp & Paper Power Generation Fisheries

EXCALIBUR 1” SIMPLEX & DUPLEX SOFTENER SPECIFICATIONS Simplex & Duplex Fully Automatic Electronic Demand Commercial Water Softeners WATER SOFTENER SPECIFICATIONS • Flow Rates up to 27 USGPM • Internal Electronic Flow Meter range 0.25-27 USGPM • Fully adjustable 6 cycle valve • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differential • Duplex softeners utilize MAV controls to provide regeneration MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI CRITICAL LENGTH WIDTH HEIGHT EWS S130 27,000 30,000 30,000 10 15 5 30 20 57 90 EWS SD130 27,000 30,000 60,000 10 15 5 40 20 57 180 EWS S145 40,500 45,000 45,000 12 17 7.5 31 20 63 115 EWS SD145 40,500 45,000 90,000 12 17 7.5 42 20 63 230 EWS S160 54,000 60,000 60,000 14 19 10 34 20 62 150 EWS SD160 54,000 60,000 120,000 14 19 10 46 20 62 300 EWS S175 67,500 75,000 75,000 16 21 12.5 36 20 64 250 EWS SD175 67,500 75,000 150,000 16 21 12.5 50 20 64 500 EWS S190 81,000 90,000 90,000 17 22 15 45 24 75 350 EWS SD190 81,000 90,000 180,000 17 22 15 58 25 75 700 EWS S1120 108,000 120,000 120,000 19 24 20 48 25 75 450 EWS SD1120 108,000 120,000 240,000 19 24 20 65 25 75 900 EWS S1150 135,000 150,000 150,000 22 26 25 60 30 75 600 EWS SD1150 135,000 150,000 300,000 22 26 25 75 30 75 1,200 EWS S1180 162,000 180,000 180,000 21 25 25 60 30 75 650 EWS SD1180 162,000 180,000 360,000 21 25 25 75 30 75 1,300 EWS S1210 189,000 210,000 210,000 24 27 25 60 30 76 750 EWS SD1210 189,000 210,000 420,000 24 27 25 76 30 76 1,500 A B BRINE TANK MINERAL TANK BRINE TANK LINE MINERAL TANK DRAIN DRAIN A B FRONT VIEW INLET OUTLET 1" 1" • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3

Simplex & Duplex Fully Automatic Electronic Demand Commercial Water Softeners WATER SOFTENER SPECIFICATIONS • Flow Rates up to 78 USGPM • External Electronic Flow Meter range 0.5-75 USGPM • Fully adjustable 6 cycle valve • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • Duplex softeners utilize MAV controls to provide regeneration MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI CRITICAL LENGTH WIDTH HEIGHT EWS S15120 108,000 120,000 120,000 40 52 20 46 24 75 450 EWS SD15120 108,000 120,000 240,000 40 52 20 68 24 75 900 EWS S15150 135,000 150,000 150,000 44 57 25 46 24 74 600 EWS SD15150 135,000 150,000 300,000 44 57 25 72 24 74 1,200 EWS S15180 162,000 180,000 180,000 43 56 30 46 24 74 650 EWS SD15180 162,000 180,000 360,000 43 56 30 72 24 74 1,300 EWS S15210 189,000 210,000 210,000 50 64 35 49 24 74 700 EWS SD15210 189,000 210,000 420,000 50 64 35 82 24 74 1,400 EWS S15240 216,000 240,000 240,000 55 71 40 58 30 85 900 EWS SD15240 216,000 240,000 480,000 55 71 40 96 30 85 1,800 EWS S15300 270,000 300,000 300,000 53 68 50 58 30 85 975 EWS SD15300 270,000 300,000 600,000 53 68 50 96 30 85 1,950 EWS S15450 405,000 450,000 450,000 60 78 70 73 39 95 1,475 EWS SD15450 405,000 450,000 900,000 60 78 70 96 39 95 2,950 EXCALIBUR 1.5” SIMPLEX & DUPLEX SOFTENER SPECIFICATIONS A B FRONT VIEW BRINE TANK BRINE TANK LINE INLET OUTLET DRAIN DRAIN B MINERAL TANK A MINERAL TANK 1.5" 1.5" • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3

A B B A FRONT VIEW BRINE TANK MINERAL TANK BRINE TANK LINE INLET OUTLET MINERAL TANK DRAIN DRAIN 3 2" 2" MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI CRITICAL LENGTH WIDTH HEIGHT EWS S2MQC120 108,000 120,000 120,000 47 60 20 45 24 75 500 EWS SD2MQC120 108,000 120,000 240,000 47 60 20 68 24 75 1,000 EWS S2MQC150 135,000 150,000 150,000 54 70 25 46 24 74 650 EWS SD2MQC150 135,000 150,000 300,000 54 70 25 72 24 74 1,300 EWS S2MQC180 162,000 180,000 180,000 52 67 30 46 24 74 700 EWS SD2MQC180 162,000 180,000 360,000 52 67 30 72 24 74 1,400 EWS S2MQC210 189,000 210,000 210,000 68 88 35 49 24 74 750 EWS SD2MQC210 189,000 210,000 420,000 68 88 35 82 24 74 1,500 EWS S2MQC240 216,000 240,000 240,000 77 100 40 58 30 85 950 EWS SD2MQC240 216,000 240,000 480,000 77 100 40 96 30 85 1,900 EWS S2MQC300 270,000 300,000 300,000 75 97 50 58 30 85 1,025 EWS SD2MQC300 270,000 300,000 600,000 75 97 50 96 30 85 2,050 EWS S2MQC450 405,000 450,000 450,000 88 113 75 73 39 95 1,500 EWS SD2MQC450 405,000 450,000 900,000 88 113 75 107 39 95 3,000 EWS S2MQC600 540,000 600,000 600,000 97 126 100 92 50 109 2,000 EWS SD2MQC600 540,000 600,000 1,200,000 97 126 100 130 50 109 4,000 EWS S2MQC750 675000 750,000 750,000 106 137 125 96 50 109 2,750 EWS SD2MQC750 675000 750,000 1,500,000 106 137 125 140 50 109 5,500 EWS S2MQC900 810000 900,000 900,000 103 134 125 96 50 109 3,000 EWS SD2MQC900 810000 900,000 1,800,000 103 134 125 142 50 109 6,000 EWS S2MQC1200 1080000 1,200,000 1,200,000 105 136 125 102 50 109 3,900 EWS SD2MQC1200 1080000 1,200,000 2,400,000 105 136 125 154 50 109 7,800 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 EXCALIBUR 2”QC SIMPLEX & DUPLEX SOFTENER SPECIFICATIONS • Flow Rates up to 136 USGPM • External Electronic Flow Meter range 1.5-150 USGPM • Fully adjustable 6 cycle valve • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differential • Duplex softeners utilize MAV controls to provide regeneration WATER SOFTENER SPECIFICATIONS Simplex & Duplex Fully Automatic Electronic Demand Commercial Water Softeners

INLET OUTLET FRONT VIEW 2" 2" BRINE TANK LINE DRAIN DRAIN BRINE TANK MINERAL TANK MINERAL TANK MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI System LENGTH WIDTH HEIGHT Critical Peak EWS S2H150 135,000 150,000 150,000 54 70 25 40 46 24 82 560 EWS SD2H150 135,000 150,000 300,000 54 70 50 80 72 24 82 1,120 EWS S2H180 162,000 180,000 180,000 52 67 30 48 46 24 82 610 EWS SD2H180 162,000 180,000 360,000 52 67 60 96 72 24 82 1,220 EWS S2H210 189,000 210,000 210,000 68 88 35 56 49 24 85 720 EWS SD2H210 189,000 210,000 420,000 68 88 70 112 76 24 85 1,440 EWS S2H240 216,000 240,000 240,000 77 100 40 64 58 30 89 940 EWS SD2H240 216,000 240,000 480,000 77 100 80 128 88 30 89 1,880 EWS S2H300 270,000 300,000 300,000 75 97 50 80 58 30 89 1,040 EWS SD2H300 270,000 300,000 600,000 75 97 100 160 88 30 89 2,080 EWS S2H450 405,000 450,000 450,000 88 113 75 113 73 39 96 1,515 EWS SD2H450 405,000 450,000 900,000 88 113 150 226 110 39 96 3,030 EWS S2H600 540,000 600,000 600,000 97 126 100 125 92 50 98 2,000 EWS SD2H600 540,000 600,000 1,200,000 97 126 200 250 134 50 98 4,000 EWS S2H750 675,000 750,000 750,000 106 137 125 125 96 50 109 2,750 EWS SD2H750 675,000 750,000 1,500,000 106 137 250 250 144 50 109 5,500 EWS S2H900 810,000 900,000 900,000 103 134 125 125 96 50 109 3,000 EWS SD2H900 810,000 900,000 1,800,000 103 134 250 250 144 50 109 6,000 EWS S2H1200 1,080,000 1,200,000 1,200,000 105 136 125 125 102 50 109 3,900 EWS SD2H1200 1,080,000 1,200,000 2,400,000 105 136 250 250 158 50 109 7,800 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 EXCALIBUR 2H” SIMPLEX & DUPLEX PROGRESSIVE SOFTENER SPECIFICATIONS • Flow Rates up to 136 USGPM • Internal Electronic Flow Meter range 1.5-125 USGPM • Fully adjustable 6 cycle valve • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • Duplex softeners utilize MAV controls to provide regeneration WATER SOFTENER SPECIFICATIONS Simplex & Duplex Fully Automatic Electronic Demand Commercial Water Softeners

EXCALIBUR 2H” TRIPLEX & QUADPLEX PROGRESSIVE SOFTENER SPECIFICATIONS INLET OUTLET FRONT VIEW 2" 2" BRINE TANK MINERAL TANK BRINE TANK LINE MINERAL TANK DRAIN DRAIN BRINE TANK MINERAL TANK Triplex & Quadplex Fully Automatic Electronic Demand Industrial Water Softeners MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI System LENGTH WIDTH HEIGHT Critical Peak EWS ST2H150 135,000 150,000 450,000 54 70 75 120 150 24 82 1,680 EWS SQ2H150 135,000 150,000 600,000 54 70 100 160 200 24 82 2,240 EWS ST2H180 162,000 180,000 540,000 52 67 90 144 150 24 82 1,830 EWS SQ2H180 162,000 180,000 720,000 52 67 120 192 200 24 82 2,440 EWS ST2H210 189,000 210,000 630,000 68 88 105 168 160 24 85 2,160 EWS SQ2H210 189,000 210,000 840,000 68 88 140 224 211 24 85 2,880 EWS ST2H240 216,000 240,000 720,000 77 100 120 192 182 30 89 2,820 EWS SQ2H240 216,000 240,000 960,000 77 100 160 256 246 30 89 3,760 EWS ST2H300 270,000 300,000 900,000 75 97 150 240 182 30 89 3,120 EWS SQ2H300 270,000 300,000 1,200,000 75 97 200 320 246 30 89 4,160 EWS ST2H450 405,000 450,000 1,350,000 88 113 225 339 227 39 96 4,545 EWS SQ2H450 405,000 450,000 1,800,000 88 113 300 452 308 39 96 6,060 EWS ST2H600 540,000 600,000 1,800,000 97 126 300 375 280 50 98 6,000 EWS SQ2H600 540,000 600,000 2,400,000 97 126 400 500 385 50 98 8,000 EWS ST2H750 675,000 750,000 2,250,000 106 137 375 375 296 50 109 8,250 EWS SQ2H750 675,000 750,000 3,000,000 106 137 500 500 400 50 109 11,000 EWS ST2H900 810,000 900,000 2,700,000 103 134 375 375 296 50 109 9,000 EWS SQ2H900 810,000 900,000 3,600,000 103 134 500 500 400 50 109 12,000 EWS ST2H1200 1,080,000 1,200,000 3,600,000 105 136 375 375 318 50 109 11,700 EWS SQ2H1200 1,080,000 1,200,000 4,800,000 105 136 500 500 424 50 109 15,600 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 • Flow Rates up to 500 USGPM • System designs up to 4 vessels • Internal Electronic Flow Meter • Fully adjustable 9 cycle valve • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • Triplex & Quad softeners utilize NHWB valves to initiate regenerations and progressive flow system operations WATER SOFTENER SPECIFICATIONS

Simplex & Duplex Fully Automatic Electronic Demand Industrial Water Softeners MINERAL TANK BRINE TANK LINE FRONT VIEW INLET OUTLET BRINE TANK DRAIN MINERAL TANK DRAIN 3" 3" MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI System LENGTH WIDTH HEIGHT Critical Peak EWS S3300 270,000 300,000 300,000 98 126 50 80 58 30 90 1,045 EWS SD3300 270,000 300,000 600,000 98 126 100 160 88 30 90 2,090 EWS S3450 405,000 450,000 450,000 144 186 75 120 73 39 97 1,520 EWS SD3450 405,000 450,000 900,000 144 186 150 240 110 39 97 3,040 EWS S3600 540,000 600,000 600,000 172 222 100 160 92 50 99 2,000 EWS SD3600 540,000 600,000 1,200,000 172 222 200 320 134 50 99 4,000 EWS S3750 675,000 750,000 750,000 190 244 125 200 96 50 110 2,845 EWS SD3750 675,000 750,000 1,500,000 190 244 250 400 144 50 110 5,690 EWS S3900 810,000 900,000 900,000 186 240 150 240 96 50 110 3,100 EWS SD3900 810,000 900,000 1,800,000 186 240 300 480 144 50 110 6,200 EWS S31200 1,080,000 1,200,000 1,200,000 194 251 200 250 102 50 107 3,900 EWS SD31200 1,080,000 1,200,000 2,400,000 194 251 400 500 158 50 107 7,800 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 EXCALIBUR 3” SIMPLEX & DUPLEX PROGRESSIVE SOFTENER SPECIFICATIONS • Flow Rates up to 500 USGPM • External Electronic Flow Meter range 3.5-350 USGPM • Fully adjustable 9 cycle valve • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • Duplex softeners utilize NHWB valves to initiate regenerations and progressive flow system operations WATER SOFTENER SPECIFICATIONS

EXCALIBUR 3” TRIPLEX & QUADPLEX PROGRESSIVE SOFTENER SPECIFICATIONS MINERAL TANK BRINE TANK LINE FRONT VIEW INLET OUTLET BRINE TANK DRAIN MINERAL TANK DRAIN BRINE TANK LINE BRINE TANK 3" 3" MINERAL TANK DRAIN Triplex & Quadplex Fully Automatic Electronic Demand Industrial Water Softeners MODEL Capacity 10lbs/ft³ Capacity 15lbs/ft³ Max System Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (in) Shipping Weight lbs 15PSI 25PSI System LENGTH WIDTH HEIGHT Critical Peak EWS ST3300 270,000 300,000 900,000 98 126 150 240 190 30 90 3,135 EWS SQ3300 270,000 300,000 1,200,000 98 126 200 320 260 30 90 4,180 EWS ST3450 405,000 450,000 1,350,000 144 186 225 360 235 39 97 4,560 EWS SQ3450 405,000 450,000 1,800,000 144 186 300 480 325 39 97 6,080 EWS ST3600 540,000 600,000 1,800,000 172 222 300 480 285 50 99 6,000 EWS SQ3600 540,000 600,000 2,400,000 172 222 400 640 380 50 99 8,000 EWS ST3750 675,000 750,000 2,250,000 190 244 375 600 300 50 110 8,535 EWS SQ3750 675,000 750,000 3,000,000 190 244 500 800 400 50 110 11,380 EWS ST3900 810,000 900,000 2,700,000 186 240 450 720 300 50 110 9,300 EWS SQ3900 810,000 900,000 3,600,000 186 240 600 960 400 50 110 12,400 EWS ST31200 1,080,000 1,200,000 3,600,000 194 251 600 750 320 50 107 11,700 EWS SQ31200 1,080,000 1,200,000 4,800,000 194 251 800 1000 430 50 107 15,600 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 • Flow Rates up to 1000 USGPM • System designs up to 4 vessels • External Electronic Flow Meter • Fully adjustable 9 cycle valve • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • Triplex & Quad softeners utilize NHWB valves to initiate regenerations and progressive flow system operations WATER SOFTENER SPECIFICATIONS

EXCALIBUR 1” COMMERCIAL/INDUSTRIAL SYSTEM CONTROLLER PROGRESSIVE SOFTENER SPECIFICATIONS A B BRINE TANK MINERAL TANK BRINE TANK LINE MINERAL TANK DRAIN DRAIN FRONT VIEW INLET OUTLET B MINERAL TANK DRAIN BRINE TANK BRINE TANK LINE Ø 1" Ø 1" MODEL1 Vessel Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (INCHES) SHIPPING WEIGHT LBS Min. Flow Critical/ Vessel Progressive Peak Flow2 LENGTH2 WIDTH HEIGHT 10lbs/ft³ 15lbs/ft³ 2 3 4 5 6 2 3 4 5 6 EWS SC1N30 27,000 30,000 0.9 5 16 24 32 40 48 42 100 130 162 195 20 57 90 EWS SC1N45 40,500 45,000 1.1 8 24 36 48 60 72 44 102 133 166 200 20 63 115 EWS SC1N60 54,000 60,000 1.6 10 32 48 64 80 96 48 114 148 185 222 20 62 150 EWS SC1N75 67,500 75,000 1.8 13 40 60 80 100 120 50 118 160 200 240 20 64 250 EWS SC1N90 81,000 90,000 2.1 15 44 66 88 110 132 58 149 200 250 300 24 75 350 EWS SC1N120 108,000 120,000 2.8 20 48 72 96 120 144 65 160 216 270 325 25 75 450 EWS SC1N150 135,000 150,000 3.5 25 50 75 100 125 150 75 190 220 280 335 30 75 600 EWS SC1N180 162,000 180,000 3.5 30 52 78 104 130 156 75 190 220 280 335 30 75 650 EWS SC1N210 189,000 210,000 4.8 35 54 81 108 135 162 76 190 230 290 345 30 76 750 System Controller 1” Fully Automatic Multi-Tank Electronic Demand Commercial/Industrial Water Softeners • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 1 = N must be replaced by number of Vessels to order. 2 = Numbers given below denote the number of vessels. • Flow Rates up to 162 USGPM • System designs up to 6 vessels • Internal Electronic Flow Meters • Fully adjustable 6 cycle valve • Eliminates potential channelling for low flow conditions • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • System Controller Softeners utilize NHWB valves to initiate regenerations and progressive flow system operations WATER SOFTENER SPECIFICATIONS

EXCALIBUR 1.5” COMMERCIAL/INDUSTRIAL SYSTEM CONTROLLER PROGRESSIVE SOFTENER SPECIFICATIONS BRINE TANK BRINE TANK LINE B MINERAL TANK A MINERAL TANK FRONT VIEW DRAIN DRAIN INLET OUTLET A MINERAL TANK DRAIN BRINE TANK BRINE TANK LINE 1.5" 1.5" System Controller 1.5” Fully Automatic Multi-Tank Electronic Demand Commercial/Industrial Water Softeners WATER SOFTENER SPECIFICATIONS • Flow Rates up to 420 USGPM • System designs up to 6 vessels • External Electronic Flow Meter • Fully adjustable 6 cycle valve • Eliminates potential channelling for low flow conditions • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • System Controller Softeners utilize NHWB valves to initiate regenerations and progressive flow system operations MODEL1 Vessel Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (INCHES) SHIPPING WEIGHT LBS Min. Flow Critical/ Vessel Progressive Peak Flow2 LENGTH2 WIDTH HEIGHT 10lbs/ft³ 15lbs/ft³ 2 3 4 5 6 2 3 4 5 6 EWS SC15N120 108,000 120,000 2.8 20 64 96 128 160 192 66 140 190 245 300 24 75 450 EWS SC15N150 135,000 150,000 3.5 25 80 120 160 200 240 75 150 205 260 315 24 74 600 EWS SC15N180 162,000 180,000 3.5 30 96 144 192 240 288 75 150 205 260 315 24 74 650 EWS SC15N210 189,000 210,000 4.8 35 112 168 224 280 336 78 160 214 275 330 24 74 700 EWS SC15N240 216,000 240,000 6.3 40 128 192 256 320 384 92 186 248 320 385 30 85 900 EWS SC15N300 270,000 300,000 6.3 50 136 204 272 340 408 92 186 248 320 385 30 85 975 EWS SC15N450 405,000 450,000 9.8 75 140 210 280 350 420 102 210 290 355 425 39 95 1,475 • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 1 = N must be replaced by number of Vessels to order. 2 = Numbers given below denote the number of vessels.

EXCALIBUR 2”QC COMMERCIAL/INDUSTRIAL SYSTEM CONTROLLER PROGRESSIVE SOFTENER SPECIFICATIONS FRONT VIEW BRINE TANK BRINE TANK LINE DRAIN INLET OUTLET DRAIN MINERAL TANK MINERAL TANK BRINE TANK BRINE TANK LINE DRAIN MINERAL TANK 2" 2" System Controller 2” Fully Automatic Multi-Tank Electronic Demand Commercial/Industrial Water Softeners • Critical maximum flow rate refers to soft water feed to boilers, heat exchangers, reverse osmosis systems or any other equipment sensitive to hard water scaling flow rate not exceeding 5gpm/ft3 1 = N must be replaced by number of Vessels to order. 2 = Numbers given below denote the number of vessels. WATER SOFTENER SPECIFICATIONS • Flow Rates up to 750 USGPM • System designs up to 6 vessels • External Electronic Flow Meters • Fully adjustable 6 cycle valve • Eliminates potential channelling for low flow conditions • Progressive flow on demand soft water • Four methods to initiate regeneration metered immediate, metered delayed, time clock delayed, or pressure differiential • System Controller Softeners utilize NHWB valves to initiate regenerations and progressive flow system operations MODEL1 Vessel Capacity (gr) FLOW RATE (GPM) APPROX. SPACE REQUIRED (INCHES) SHIPPING WEIGHT LBS Min. Flow Critical/ Vessel Progressive Peak Flow2 LENGTH2 WIDTH HEIGHT 10lbs/ft³ 15lbs/ft³ 2 3 4 5 6 2 3 4 5 6 EWS SC2MQCN120 108,000 120,000 2.8 20 64 96 128 160 192 68 140 188 236 284 24 75 500 EWS SC2MQCN150 135,000 150,000 3.5 25 80 120 160 200 240 72 146 196 246 296 24 74 650 EWS SC2MQCN180 162,000 180,000 3.5 30 96 144 192 240 288 72 146 196 246 296 24 74 700 EWS SC2MQCN210 189,000 210,000 4.8 35 112 168 224 280 336 82 155 208 262 314 24 74 750 EWS SC2MQCN240 216,000 240,000 6.3 40 128 192 256 320 384 96 182 244 306 368 30 85 950 EWS SC2MQCN300 270,000 300,000 6.3 50 160 240 320 400 480 96 182 244 306 368 30 85 1,025 EWS SC2MQCN450 405,000 450,000 9.8 75 226 339 452 565 678 107 227 304 382 458 39 95 1,500 EWS SC2MQCN600 540,000 600,000 14.1 100 250 375 500 625 750 130 284 340 426 512 50 109 2,000 EWS SC2MQCN750 675,000 750,000 19.2 125 250 375 500 625 750 140 296 396 496 596 50 109 2,750 EWS SC2MQCN900 810,000 900,000 19.2 125 250 375 500 625 750 140 296 396 496 596 50 109 3,000 EWS SC2MQCN1200 1,080,000 1,200,000 25.0 125 250 375 500 625 750 154 314 420 526 632 50 109 3,900

EXCALIBUR WATER SYSTEMS TF. 877 733 8999 E. [email protected] www.excaliburwater.com

RkJQdWJsaXNoZXIy NTc4ODc=