Excalibur Commercial Reverse Osmosis Systems Brochure

Excalibur SFIN-Series Reverse Osmosis Systems MODEL PERMEATE FEED CONCENTRATE Recirculation Flow (GPM) Membrane Quantity VESSEL ELECTRICAL REQUIREMENTS WEIGHT (LBS) SPACE REQUIRED (ft) Flow (GPM) Line Size (inch) Flow (GPM) Line Size (inch) Flow (GPM) Line Size (inch) Qty Array Voltage Phase Max Load Amperes Pump (HP) L W H RO SFIN12 60 2.0 80 2.0 20 1.5 2.0 12 4 2:1:1 575 3 11 10 3,000 13 5 8.5 RO SFIN18 90 3.0 120 3.0 30 1.5 2.0 18 6 3:2:1 575 3 17 15 3,500 13 5 8.5 RO SFIN28 125 3.0 167 3.0 42 1.5 2.5 28 7 4:2:1 575 3 34 15x2 4,500 17 6.5 8.5 RO SFIN32 160 3.0 224 4.0 64 2.0 10 32 8 4:3:1 575 3 34 15x2 4,700 17 6.5 8.5 RO SFIN48 215 4.0 287 4.0 72 2.0 40 48 12 6:4:2 575 3 34 15x2 6,500 17 6.5 8.5 RO SFIN72 325 5.0 433 5.0 108 3.0 60 72 18 10:5:3 575 3 51 15x3 7,500 17 10 8.5 RO SFIN96 430 5.0 574 6.0 144 3.0 20 96 24 12:8:4 575 3 81 25x3 9,000 17 12 8.5 Recirculation flow and waste flow rates given are nominal and can change by changing inlet water properties. Contact Excalibur for flow rates higher than 430 GPM. SFIN SERIES INDUSTRIAL REVERSE OSMOSIS SPECIFICATIONS • Flow rates to 1000 USGPM • Salt rejection rate over 99 percent NSF • 75 percent permeate recovery from feed water • Performance data calculated by ROSA software • Low pressure membranes reduces pump HP • CSA / ESA / UL Certified • Series 200 or 250 controller for automated process • Vertical multistage pump for boosting pressure • Diaphragm valve for pre-treatment lockout • Hall effect electronic flow meters with live reading LED displays • TDS and PH sensor monitoring and display

RkJQdWJsaXNoZXIy NTc4ODc=